Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406A 0515 Self test detected memory DIMM fault Memory DIMM 19, riser 2
Location: U1.1-P1-M2.19
406A 0516 Self test detected memory DIMM fault Memory DIMM 20, riser 2
Location: U1.1-P1-M2.20
406A 0517 Self test detected memory DIMM fault Memory DIMM 27, riser 2
Location: U1.1-P1-M2.27
406A 0518 Self test detected memory DIMM fault Memory DIMM 28, riser 2
Location: U1.1-P1-M2.28
406A 051D Self test detected memory DIMM group fault Memory octal B, riser 2
Location: U1.1-P1-M2.3 x8
406A 051E Self test detected memory DIMM group fault Memory quad B odd, riser 2
Location: U1.1-P1-M2.3 x4
406A 051F Self test detected memory DIMM group fault Memory quad B even, riser 2
Location: U1.1-P1-M2.4 x4
406A 0521 Self test detected memory DIMM fault Memory DIMM 5, riser 2
Location: U1.1-P1-M2.5
406A 0522 Self test detected memory DIMM fault Memory DIMM 6, riser 2
Location: U1.1-P1-M2.6
406A 0523 Self test detected memory DIMM fault Memory DIMM 13, riser 2
Location: U1.1-P1-M2.13
406A 0524 Self test detected memory DIMM fault Memory DIMM 14, riser 2
Location: U1.1-P1-M2.14
406A 0525 Self test detected memory DIMM fault Memory DIMM 21, riser 2
Location: U1.1-P1-M2.21
406A 0526 Self test detected memory DIMM fault Memory DIMM 22, riser 2
Location: U1.1-P1-M2.22
406A 0527 Self test detected memory DIMM fault Memory DIMM 29, riser 2
Location: U1.1-P1-M2.29
406A 0528 Self test detected memory DIMM fault Memory DIMM 30, riser 2
Location: U1.1-P1-M2.30
406A 052D Self test detected memory DIMM group fault Memory octal C, riser 2
Location: U1.1-P1-M2.5 x8
406A 052E Self test detected memory DIMM group pair
A fault
Memory quad C odd, riser 2
Location: U1.1-P1-M2.5 x4
406A 052F Self test detected memory DIMM group fault Memory quad C even, riser 2
Location: U1.1-P1-M2.6 x4
406A 0531 Self test detected memory DIMM fault Memory DIMM 7, riser 2
Location: U1.1-P1-M2.7
406A 0532 Self test detected memory DIMM fault Memory DIMM 8, riser 2
Location: U1.1-P1-M2.8
406A 0533 Self test detected memory DIMM fault Memory DIMM 15, riser 2
Location: U1.1-P1-M2.15
406A 0534 Self test detected memory DIMM fault Memory DIMM 16, riser 2
Location: U1.1-P1-M2.16
406A 0535 Self test detected memory DIMM fault Memory DIMM 23, riser 2
Location: U1.1-P1-M2.23