Table  7.  Service  Processor  Error  Codes  (continued) 
Error  Code  Description  Action/ 
Possible  Failing  FRU 
406B  0231  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  7,  riser  1 
Location:  U1.1-P1-M1.7 
406B  0232  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  8,  riser  1 
Location:  U1.1-P1-M1.8 
406B  0233  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  15,  riser  1 
Location:  U1.1-P1-M1.15 
406B  0234  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  16,  riser  1 
Location:  U1.1-P1-M1.16 
406B  0235  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  23,  riser  1 
Location:  U1.1-P1-M1.23 
406B  0236  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  24,  riser  1 
Location:  U1.1-P1-M1.24 
406B  0237  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  31,  riser  1 
Location:  U1.1-P1-M1.31 
406B  0238  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  32,  riser  1 
Location:  U1.1-P1-M1.32 
406B  023D  Wire  test  detected  memory  DIMM  group  fault  Memory  octal  D,  riser  1 
Location:  U1.1-P1-M1.7  x8 
406B  023E  Wire  test  detected  memory  DIMM  group  fault  Memory  quad  D  odd,  riser  1 
Location:  U1.1-P1-M1.7  x4 
406B  023F  Wire  test  detected  memory  DIMM  group  fault  Memory  quad  D  even,  riser  1 
Location:  U1.1-P1-M1.8  x4 
406B  02FF  Wire  test  detected  memory  on  riser  fault  All  memory  on  riser  1 
Location:  U1.1-P1-M1.1  x32 
Memory  failure  on  riser  card  1  that  cannot  be 
automatically  isolated.  go  to  “MAP  1540: 
Minimum  Configuration”  on  page  110  and  run 
CEC  drawer  minimum  configuration  for 
further  isolation. 
406B  0300  Wire  test  detected  processor  card  fault  Processor  card 
Location:  U1.1-P1-C1 
406B  0400  Wire  test  detected  processor  card  fault  Processor  card 
Location:  U1.1-P1-C2 
406B  0500  Wire  test  detected  memory  riser  card  fault  Memory  riser  card  2 
Location:  U1.1-P1-M1 
406B  0501  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  1,  riser  2 
Location:  U1.1-P1-M2.1 
406B  0502  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  2,  riser  2 
Location:  U1.1-P1-M2.2 
406B  0503  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  9,  riser  2 
Location:  U1.1-P1-M2.9 
406B  0504  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  10,  riser  2 
Location:  U1.1-P1-M2.10 
406B  0505  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  17,  riser  2 
Location:  U1.1-P1-M2.17 
406B  0506  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  18,  riser  2 
Location:  U1.1-P1-M2.18 
 
244  Service  Guide