Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406B 0231 Wire test detected memory DIMM fault Memory DIMM 7, riser 1
Location: U1.1-P1-M1.7
406B 0232 Wire test detected memory DIMM fault Memory DIMM 8, riser 1
Location: U1.1-P1-M1.8
406B 0233 Wire test detected memory DIMM fault Memory DIMM 15, riser 1
Location: U1.1-P1-M1.15
406B 0234 Wire test detected memory DIMM fault Memory DIMM 16, riser 1
Location: U1.1-P1-M1.16
406B 0235 Wire test detected memory DIMM fault Memory DIMM 23, riser 1
Location: U1.1-P1-M1.23
406B 0236 Wire test detected memory DIMM fault Memory DIMM 24, riser 1
Location: U1.1-P1-M1.24
406B 0237 Wire test detected memory DIMM fault Memory DIMM 31, riser 1
Location: U1.1-P1-M1.31
406B 0238 Wire test detected memory DIMM fault Memory DIMM 32, riser 1
Location: U1.1-P1-M1.32
406B 023D Wire test detected memory DIMM group fault Memory octal D, riser 1
Location: U1.1-P1-M1.7 x8
406B 023E Wire test detected memory DIMM group fault Memory quad D odd, riser 1
Location: U1.1-P1-M1.7 x4
406B 023F Wire test detected memory DIMM group fault Memory quad D even, riser 1
Location: U1.1-P1-M1.8 x4
406B 02FF Wire test detected memory on riser fault All memory on riser 1
Location: U1.1-P1-M1.1 x32
Memory failure on riser card 1 that cannot be
automatically isolated. go to “MAP 1540:
Minimum Configuration” on page 110 and run
CEC drawer minimum configuration for
further isolation.
406B 0300 Wire test detected processor card fault Processor card
Location: U1.1-P1-C1
406B 0400 Wire test detected processor card fault Processor card
Location: U1.1-P1-C2
406B 0500 Wire test detected memory riser card fault Memory riser card 2
Location: U1.1-P1-M1
406B 0501 Wire test detected memory DIMM fault Memory DIMM 1, riser 2
Location: U1.1-P1-M2.1
406B 0502 Wire test detected memory DIMM fault Memory DIMM 2, riser 2
Location: U1.1-P1-M2.2
406B 0503 Wire test detected memory DIMM fault Memory DIMM 9, riser 2
Location: U1.1-P1-M2.9
406B 0504 Wire test detected memory DIMM fault Memory DIMM 10, riser 2
Location: U1.1-P1-M2.10
406B 0505 Wire test detected memory DIMM fault Memory DIMM 17, riser 2
Location: U1.1-P1-M2.17
406B 0506 Wire test detected memory DIMM fault Memory DIMM 18, riser 2
Location: U1.1-P1-M2.18