Table  7.  Service  Processor  Error  Codes  (continued) 
Error  Code  Description  Action/ 
Possible  Failing  FRU 
406B  020F  Wire  test  detected  memory  DIMM  group  fault  Memory  quad  A  even,  riser  1 
Locations:  U1.1-P1-M1.2  x4 
406B  0211  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  3,  riser  1 
Location:  U1.1-P1-M1.3 
406B  0212  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  4,  riser  1 
Location:  U1.1-P1-M1.4 
406B  0213  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  11,  riser  1 
Location:  U1.1-P1-M1.11 
406B  0214  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  12,  riser  1 
Location:  U1.1-P1-M1.12 
406B  0215  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  19,  riser  1 
Location:  U1.1-P1-M1.19 
406B  0216  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  20,  riser  1 
Location:  U1.1-P1-M1.20 
406B  0217  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  27,  riser  1 
Location:  U1.1-P1-M1.27 
406B  0218  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  28,  riser  1 
Location:  U1.1-P1-M1.28 
406B  021D  Wire  test  detected  memory  DIMM  group  fault  Memory  octal  B,  riser  1 
Location:  U1.1-P1-M1.3  x8 
406B  021E  Wire  test  detected  memory  DIMM  group  pair 
A  fault 
Memory  quad  B  odd,  riser  1 
Location:  U1.1-P1-M1.3  x4 
406B  021F  Wire  test  detected  memory  DIMM  group  fault  Memory  quad  B  even,  riser  1 
Location:  U1.1-P1-M1.4  x4 
406B  0221  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  5,  riser  1 
Location:  U1.1-P1-M1.5 
406B  0222  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  6,  riser  1 
Location:  U1.1-P1-M1.6 
406B  0223  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  13,  riser  1 
Location:  U1.1-P1-M1.13 
406B  0224  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  14,  riser  1 
Location:  U1.1-P1-M1.14 
406B  0225  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  21,  riser  1 
Location:  U1.1-P1-M1.21 
406B  0226  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  22,  riser  1 
Location:  U1.1-P1-M1.22 
406B  0227  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  29,  riser  1 
Location:  U1.1-P1-M1.29 
406B  0228  Wire  test  detected  memory  DIMM  fault  Memory  DIMM  30,  riser  1 
Location:  U1.1-P1-M1.30 
406B  022D  Wire  test  detected  memory  DIMM  group  fault  Memory  octal  C,  riser  1 
Locations:  U1.1-P1-M1.5  x8 
406B  022E  Wire  test  detected  memory  DIMM  group  pair 
A  fault 
Memory  quad  C  odd,  riser  1 
Locations:  U1.1-P1-M1.5  x4 
406B  022F  Wire  test  detected  memory  DIMM  group  fault  Memory  quad  C  even,  riser  1 
Locations:  U1.1-P1-M1.6  x4 
 
Chapter  5.  Error  Code  to  FRU  Index  243