Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406B 020F Wire test detected memory DIMM group fault Memory quad A even, riser 1
Locations: U1.1-P1-M1.2 x4
406B 0211 Wire test detected memory DIMM fault Memory DIMM 3, riser 1
Location: U1.1-P1-M1.3
406B 0212 Wire test detected memory DIMM fault Memory DIMM 4, riser 1
Location: U1.1-P1-M1.4
406B 0213 Wire test detected memory DIMM fault Memory DIMM 11, riser 1
Location: U1.1-P1-M1.11
406B 0214 Wire test detected memory DIMM fault Memory DIMM 12, riser 1
Location: U1.1-P1-M1.12
406B 0215 Wire test detected memory DIMM fault Memory DIMM 19, riser 1
Location: U1.1-P1-M1.19
406B 0216 Wire test detected memory DIMM fault Memory DIMM 20, riser 1
Location: U1.1-P1-M1.20
406B 0217 Wire test detected memory DIMM fault Memory DIMM 27, riser 1
Location: U1.1-P1-M1.27
406B 0218 Wire test detected memory DIMM fault Memory DIMM 28, riser 1
Location: U1.1-P1-M1.28
406B 021D Wire test detected memory DIMM group fault Memory octal B, riser 1
Location: U1.1-P1-M1.3 x8
406B 021E Wire test detected memory DIMM group pair
A fault
Memory quad B odd, riser 1
Location: U1.1-P1-M1.3 x4
406B 021F Wire test detected memory DIMM group fault Memory quad B even, riser 1
Location: U1.1-P1-M1.4 x4
406B 0221 Wire test detected memory DIMM fault Memory DIMM 5, riser 1
Location: U1.1-P1-M1.5
406B 0222 Wire test detected memory DIMM fault Memory DIMM 6, riser 1
Location: U1.1-P1-M1.6
406B 0223 Wire test detected memory DIMM fault Memory DIMM 13, riser 1
Location: U1.1-P1-M1.13
406B 0224 Wire test detected memory DIMM fault Memory DIMM 14, riser 1
Location: U1.1-P1-M1.14
406B 0225 Wire test detected memory DIMM fault Memory DIMM 21, riser 1
Location: U1.1-P1-M1.21
406B 0226 Wire test detected memory DIMM fault Memory DIMM 22, riser 1
Location: U1.1-P1-M1.22
406B 0227 Wire test detected memory DIMM fault Memory DIMM 29, riser 1
Location: U1.1-P1-M1.29
406B 0228 Wire test detected memory DIMM fault Memory DIMM 30, riser 1
Location: U1.1-P1-M1.30
406B 022D Wire test detected memory DIMM group fault Memory octal C, riser 1
Locations: U1.1-P1-M1.5 x8
406B 022E Wire test detected memory DIMM group pair
A fault
Memory quad C odd, riser 1
Locations: U1.1-P1-M1.5 x4
406B 022F Wire test detected memory DIMM group fault Memory quad C even, riser 1
Locations: U1.1-P1-M1.6 x4
Chapter 5. Error Code to FRU Index 243