Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406B 00A5 Wire test detected invalid system
configuration
Verify system components are supported and
properly installed.
406B 00A6 Wire test detected no usable memory 1. Ensure that CEC memory is properly
installed.
2. If more than one DIMM is called out, go
to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
″Memory Configuration/Deconfiguration
Menu″ on page 374 for more information.
406B 00A7 Wire test detected hardware problem Go to minimum configuration and also run
CEC minimum configuration
406B 00B0 Wire test detected bus controller lock-unlock
failure
RIO bus adapter
Location: U0.1-P1.1
406B 00B1 Wire test detected bus controller failure RIO bus adapter
Location: U0.1-P1.1
406B 00B3 Wire test detected clock fault 1. Clock card
Location: U1.1-P1.1.1
2. CEC RIO bus adapter
Location: U1.1-P1.1
406B 00B7 Wire test detected insufficient hardware
resources to continue IPL
This error code appears after the initial
testing by the service processor firmware on
the CEC was completed correctly, but a
problem occurred when the firmware tried to
communicate outside the CEC. Suspect a
problem with the RIO interface, either cables
or adapters.
406B 0200 Wire test detected memory riser card fault Memory riser card 1
Location: U1.1-P1-M1
406B 0201 Wire test detected memory DIMM fault Memory DIMM 1, riser 1
Location: U1.1-P1-M1.1
406B 0202 Wire test detected memory DIMM fault Memory DIMM 2, riser 1
Location: U1.1-P1-M1.2
406B 0203 Wire test detected memory DIMM fault Memory DIMM 9, riser 1
Location: U1.1-P1-M1.9
406B 0204 Wire test detected memory DIMM fault Memory DIMM 10, riser 1
Location: U1.1-P1-M1.10
406B 0205 Wire test detected memory DIMM fault Memory DIMM 17, riser 1
Location: U1.1-P1-M1.17
406B 0206 Wire test detected memory DIMM fault Memory DIMM 18, riser 1
Location: U1.1-P1-M1.18
406B 0207 Wire test detected memory DIMM fault Memory DIMM 25, riser 1
Location: U1.1-P1-M1.25
406B 0208 Wire test detected memory DIMM fault Memory DIMM 26, riser 1
Location: U1.1-P1-M1.26
406B 020D Wire test detected memory DIMM group fault Memory octal A, riser 1
Location: U1.1-P1-M1.1 x8
406B 020E Wire test detected memory DIMM group fault Memory quad A odd, riser 1
Locations: U1.1-P1-M1.1 x4