EasyManua.ls Logo

IBM RS/6000 Enterprise Server M80 - Page 259

IBM RS/6000 Enterprise Server M80
567 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
406A 3141 Self test detected RIO hub 1 fault CEC RIO bus adapter
Location: U1.1-P1.1
406A 31FF Self test detected RIO port fault CEC RIO bus adapter
Location: U1.1-P1.1
406A 3200 Self test detected primary I/O drawer fault Go to “MAP 1540: Minimum Configuration”
on page 110.
406A 3201 Self test detected primary I/O drawer
backplane fault
Primary I/O drawer backplane
Location: U0.1-P1
406A 3280 Self test detected primary RIO adapter fault Primary RIO adapter
Location: U0.1-P1.1
406A 3281 Self test detected primary RIO port 0 fault 1. Check RIO cable
Location: U0.1-P1.1/Q1
2. RIO bus adapter
Location: U0.1-P1.1
406A 3282 Self test detected primary RIO port 1 fault 1. Check RIO cable
Location: U0.1-P1.1/Q2
2. RIO bus adapter
Location: U0.1-P1.1
406A 3283 Self test detected primary RIO ports fault RIO bus adapter
Location: U0.1-P1.1
406A 3284 Self test detected PCI controller PHB0 1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
406A 3285 Self test detected PCI controller PHB1 1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
406A 3286 Self test detected PCI controller PHB2 1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
406B 0001 Wire test detected CEC backplane failure CEC backplane
Location: U1.1-P1
406B 0003 Wire test detected processor fault All processors
Location: U1.1-P1-C1
406B 0009 Wire test detected memory fault All memory
Location: U1.1-P1-M1 x2
406B 00A0 Wire test detected CSP service processor
firmware fault
Update system firmware
Location: U0.1-P1/Y1
406B 00A1 Wire test detected AIX or system firmware
fault
1. Check for AIX updates
2. Check for system firmware updates
Location: U0.1-P1/Y1
406B 00A2 Wire test detected service processor firmware
(processor runtime diagnostics) fault
Check for system firmware updates
Location: U0.1-P1/Y1
406B 00A3 Wire test detected memory plugging fault All pluggable memory
406B 00A4 Wire test detected application caused fault Application software
Chapter 5. Error Code to FRU Index 241

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Related product manuals