Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
460B 285D I/O system and wire test detected SPCN fan
controller fault
1. SPCN fan controller
Location: U0.1-X2
2. I/O drawer power distribution board
Location: U0.1-X1
460B 288A I/O system and wire test detected memory
riser card fault
1. Go to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
Memory Configuration/Deconfiguration
Menu on page 374 for more information.
2. Memory riser card
Locations: U1.1-P1-M1
U1.1-P1-M2
460B 300A I/O system and wire test detected 32 MB
DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460B 300B I/O system and wire test detected 128 MB
DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460B 300C I/O system and wire test detected 256 MB
DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460B 300D I/O system and wire test detected 512 MB
(stacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460B 300E I/O system and wire test detected 512 MB
(unstacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460B 301F I/O system and wire test detected 128 MB
DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460B 303A I/O system and wire test detected 1 GB
DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460B 515B I/O system and wire test detected 1100W ac
power supply fault
1100W ac power supply
Locations: U1.1-V1
U1.1-V2
460B 51AC I/O system and wire test detected 595W ac
power supply fault
595W ac power supply
Locations: U0.1-V1
U0.1-V2
460B 51AD I/O system and wire test detected 595W dc
power supply fault
595W dc power supply
Locations: U0.1-V1
U0.1-V2
460B 51AE I/O system and wire test detected 1100W dc
power supply fault
1100W dc power supply
Locations: U1.1-V1
U1.1-V2
460C 245B I/O system and IPL MOPS detected 2W 4M
processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Chapter 5. Error Code to FRU Index 307