Table  7.  Service  Processor  Error  Codes  (continued) 
Error  Code  Description  Action/ 
Possible  Failing  FRU 
460C  245C  I/O  system  and  IPL  MOPS  detected  2W  2M 
processor  fault 
Processor  card 
Locations:  U1.1-P1-C1 
U1.1-P1-C2 
460C  245D  I/O  system  and  IPL  MOPS  detected  4W  4M 
processor  fault 
Processor  card 
Locations:  U1.1-P1-C1 
U1.1-P1-C2 
460C  248B  I/O  system  and  IPL  MOPS  detected  primary 
I/O  drawer  operator  panel  fault 
Operator  Panel 
Location:  U0.1-L1 
460C  24A5  I/O  system  and  IPL  MOPS  detected  2W  500 
MHz  processor  fault 
Processor  card 
Locations:  U1.1-P1-C1 
U1.1-P1-C2 
460C  24A6  I/O  system  and  IPL  MOPS  detected  4W  500 
MHz  processor  fault 
Processor  card 
Locations:  U1.1-P1-C1 
U1.1-P1-C2 
460C  25AB  I/O  system  and  IPL  MOPS  detected  400  MHz 
clock  fault 
400  MHz  clock 
Location:  U1.1-P1.1.1 
460C  25AD  I/O  system  and  IPL  MOPS  detected  540  MHz 
clock  fault 
540  MHz  clock 
Location:  U1.1-P1.1.1 
460C  25B1  I/O  system  and  IPL  MOPS  detected  750  MHz 
clock  fault 
750  MHz  clock 
Location:  U1.1-P1.1.1 
460C  25B3  I/O  system  and  IPL  MOPS  detected  4W  750 
MHz  processor  fault 
Processor  card 
Locations:  U1.1-P1-C1 
U1.1-P1-C2 
460C  25B4  I/O  system  and  IPL  MOPS  detected  2W  750 
MHz  processor  fault 
Processor  card 
Locations:  U1.1-P1-C1 
U1.1-P1-C2 
460C  25DA  I/O  system  and  IPL  MOPS  detected  500  MHz 
clock  fault 
500  MHz  clock 
Location:  U1.1-P1.1.1 
460C  267D  I/O  system  and  wire  test  detected  an  8W, 
750  MHz  regulator  fault 
8W  regulator  card 
Location:  U1.1-P1-V1 
460C  2687  I/O  system  and  IPL  MOPS  detected  remote 
I/O  bus  adapter  fault 
Remote  I/O  bus  adapter 
Location:  U1.1-P1.1 
460C  271A  I/O  system  and  IPL  MOPS  detected  primary 
I/O  planar  fault 
Primary  I/O  planar 
Location:  U0.1-P1 
460C  271D  I/O  system  and  IPL  MOPS  detected 
secondary  I/O  planar  fault 
Secondary  I/O  planar 
Locations:  U0.2-P1 
U0.3-P1 
U0.4-P1 
460C  2733  I/O  system  and  IPL  MOPS  detected  I/O  clock 
fault 
CEC  RIO  bus  adapter 
Location:  U1.1-P1.1 
460C  27AA  I/O  system  and  IPL  MOPS  detected  a  2W/4W 
regulator  fault 
2W/4W  regulator  card 
Location:  U1.1-P1-V1 
460C  27AB  I/O  system  and  IPL  MOPS  detected  an  8W 
regulator  fault 
8W  regulator  card 
Location:  U1.1-P1-V1 
460C  281C  I/O  system  and  IPL  MOPS  detected  CEC 
backplane  fault 
CEC  backplane 
Location:  U1.1-P1 
460C  281D  I/O  system  and  IPL  MOPS  detected  Model 
6M1  CEC  backplane  fault 
CEC  backplane 
Location:  U1.1-P1 
 
308  Service  Guide