Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
460D 285D I/O system and attention handler detected
SPCN fan controller fault
1. SPCN fan controller
Location: U0.1-X2
2. I/O drawer power distribution board
Location: U0.1-X1
460D 288A I/O system and attention handler detected
memory riser card fault
1. Go to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
″Memory Configuration/Deconfiguration
Menu″ on page 374 for more information.
2. Memory riser card
Locations: U1.1-P1-M1
U1.1-P1-M2
460D 300A I/O system and attention handler detected 32
MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460D 300B I/O system and attention handler detected
128 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460D 300C I/O system and attention handler detected
256 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460D 300D I/O system and attention handler detected
512 MB (stacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460D 300E I/O system and attention handler detected
512 MB (unstacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460D 301F I/O system and attention handler detected
128 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460D 303A I/O system and attention handler detected 1
GB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
460D 515B I/O system and attention handler detected
1100W ac power supply fault
1100W ac power supply
Locations: U1.1-V1
U1.1-V2
460D 51AC I/O system and attention handler detected
595W ac power supply fault
595W ac power supply
Locations: U0.1-V1
U0.1-V2
460D 51AD I/O system and attention handler detected
595W dc power supply fault
595W dc power supply
Locations: U0.1-V1
U0.1-V2
460D 51AE I/O system and attention handler detected
1100W dc power supply fault
1100W dc power supply
Locations: U1.1-V1
U1.1-V2
460E 245B I/O system and scan control routines
detected 2W 4M processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Chapter 5. Error Code to FRU Index 311