Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
460E 245C I/O system and scan control routines
detected 2W 2M processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
460E 245D I/O system and scan control routines
detected 4W 4M processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
460E 248B I/O system and scan control routines
detected primary I/O drawer operator panel
fault
Operator Panel
Location: U0.1-L1
460E 24A5 I/O system and scan control routines
detected 2W 500 MHz processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
460E 24A6 I/O system and scan control routines
detected 4W 500 MHz processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
460E 25AB I/O system and scan control routines
detected 400 MHz clock fault
400 MHz clock
Location: U1.1-P1.1.1
460E 25AD I/O system and scan control routines
detected 540 MHz clock fault
540 MHz clock
Location: U1.1-P1.1.1
460E 25B1 I/O system and scan control routines
detected 750 MHz clock fault
750 MHz clock
Location: U1.1-P1.1.1
460E 25B3 I/O system and scan control routines
detected 4W 750 MHz processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
460E 25B4 I/O system and scan control routines
detected 2W 750 MHz processor fault
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
460E 25DA I/O system and scan control routines
detected 500 MHz clock fault
500 MHz clock
Location: U1.1-P1.1.1
460E 267D I/O system and scan control routines
detected an 8W, 750 MHz regulator fault
8W regulator card
Location: U1.1-P1-V1
460E 2687 I/O system and scan control routines
detected remote I/O bus adapter fault
Remote I/O bus adapter
Location: U1.1-P1.1
460E 271A I/O system and scan control routines
detected primary I/O planar fault
Primary I/O planar
Location: U0.1-P1
460E 271D I/O system and scan control routines
detected secondary I/O planar fault
Secondary I/O planar
Locations: U0.2-P1
U0.3-P1
U0.4-P1
460E 2733 I/O system and scan control routines
detected I/O clock fault
CEC RIO bus adapter
Location: U1.1-P1.1
460E 27AA I/O system and scan control routines
detected a 2W/4W regulator fault
2W/4W regulator card
Location: U1.1-P1-V1
460E 27AB I/O system and scan control routines
detected an 8W regulator fault
8W regulator card
Location: U1.1-P1-V1
460E 281C I/O system and scan control routines
detected CEC backplane fault
CEC backplane
Location: U1.1-P1
312 Service Guide