Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4B2E 25DA Processor system and scan control routines
detected 500 MHz clock fault
500 MHz clock
Location: U1.1-P1.1.1
4B2E 267D Processor system and scan control routines
detected an 8W, 750 MHz regulator fault
8W regulator card
Location: U1.1-P1-V1
4B2E 2687 Processor system and scan control routines
detected remote I/O bus adapter fault
Remote I/O bus adapter
Location: U1.1-P1.1
4B2E 271A Processor system and scan control routines
detected primary I/O planar fault
Primary I/O planar
Location: U0.1-P1
4B2E 271D Processor system and scan control routines
detected secondary I/O planar fault
Secondary I/O planar
Locations: U0.2-P1
U0.3-P1
U0.4-P1
4B2E 2733 Processor system and scan control routines
detected I/O clock fault
CEC RIO bus adapter
Location: U1.1-P1.1
4B2E 27AA Processor system and scan control routines
detected a 2W/4W regulator fault
2W/4W regulator card
Location: U1.1-P1-V1
4B2E 27AB Processor system and scan control routines
detected an 8W regulator fault
8W regulator card
Location: U1.1-P1-V1
4B2E 281C Processor system and scan control routines
detected CEC backplane fault
CEC backplane
Location: U1.1-P1
4B2E 281D Processor system and scan control routines
detected Model 6M1 CEC backplane fault
CEC backplane
Location: U1.1-P1
4B2E 285D Processor system and scan control routines
detected SPCN fan controller fault
1. SPCN fan controller
Location: U0.1-X2
2. I/O drawer power distribution board
Location: U0.1-X1
4B2E 288A Processor system and scan control routines
detected memory riser card fault
1. Go to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
″Memory Configuration/Deconfiguration
Menu″ on page 374 for more information.
2. Memory riser card
Locations: U1.1-P1-M1
U1.1-P1-M2
4B2E 300A Processor system and scan control routines
detected 32 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2E 300B Processor system and scan control routines
detected 128 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2E 300C Processor system and scan control routines
detected 256 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2E 300D Processor system and scan control routines
detected 512 MB (stacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2E 300E Processor system and scan control routines
detected 512 MB (unstacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Chapter 5. Error Code to FRU Index 333

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals