Table 9. Common Firmware Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
B1xx 4698 Firmware problem 1. Check for system firmware updates
2. Call second level of support
B1xx 4699 Service processor firmware error 1. Check for system firmware updates
Location: U0.1-P1/Y1
2. Call second level of support
B1xx 469A System firmware interface problem 1. Check for system firmware update
2. Call second level of support
B1xx 469B Firmware to I/O interface problem 1. Check for system firmware update
2. Primary I/O drawer backplane
Location: U0.1-P1
B1xx 469C Firmware to I/O interface problem 1. Check for system firmware update
2. Primary I/O drawer backplane
Location: U0.1-P1
B1xx 469E Possible service processor firmware problem 1. Check for system firmware updates
Location: U0.1-P1/Y1
2. Go to “MAP 1540: Minimum
Configuration” on page 110, run CEC
minimum configuration.
3. Primary I/O drawer backplane
Location:
U0.1-P1
B1xx 469F Possible service processor firmware problem 1. Check for system firmware updates
Location: U0.1-P1/Y1
2. Go to “MAP 1540: Minimum
Configuration” on page 110, run CEC
minimum configuration
3. Primary I/O drawer backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index 345

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals