Enable supplemental restart policy - The default setting is No. If set to Yes, the service processor
restarts the system when the system loses control as detected by service processor surveillance,
and either:
The Use OS-Defined restart policy is set to No.
OR
The Use OS-Defined restart policy is set to Yes, and the operating system has no automatic
restart policy.
Refer to “Service Processor Reboot/Restart Recovery” on page 387.
Call-Out before restart (enabled/disabled) - If a restart is necessary due to a system fault, you can
enable the service processor to call out and report the event. This option can be valuable if the
number of these events becomes excessive, signalling a bigger problem.
v
Power-On System
Allows immediate power-on of the system. For other power-on methods, see “Powering On the System”
on page 415.
v Power-Off System
Allows the user to power-off the system.
v Enable/Disable Fast System Boot
Allows the user to select the speed of the system boot.
Attention: Selecting the fast IPL results in several diagnostic tests being skipped and a shorter
memory test being run.
370 Service Guide