Table 25. Informational events (continued)
Event ID
Notification
type Description
980350 I The node is now a functional member of the cluster
(system).
980351 I A noncritical hardware error occurred.
980352 I Attempt to automatically recover offline node
starting.
980370 I Both nodes in the I/O group are available.
980371 I One node in the I/O group is unavailable.
980372 W Both nodes in the I/O group are unavailable.
980380 I Maintenance mode was started.
980381 I Maintenance mode has ended.
980392 I Cluster (system) recovery completed.
980435 W Failed to obtain directory listing from remote node.
980440 W Failed to transfer file from remote node.
980445 I The migration is complete.
980446 I The secure delete is complete.
980501 W The virtualization amount is close to the limit that is
licensed.
980502 W The FlashCopy feature is close to the limit that is
licensed.
980503 W The Metro Mirror or Global Mirror feature is close to
the limit that is licensed.
980504 I The limit was reached for the external virtualization
feature.
981002 I Fibre Channel discovery occurred; configuration
changes are pending.
981003 I Fibre Channel discovery occurred; configuration
changes are complete.
981004 I Fibre Channel discovery occurred; no configuration
changes were detected.
981007 W The managed disk is not on the preferred path.
981009 W The initialization for the managed disk failed.
981014 W The LUN discovery has failed. The cluster (system)
has a connection to a device through this node but
this node cannot discover the unmanaged or
managed disk that is associated with this LUN.
981015 W The LUN capacity equals or exceeds the maximum.
Only part of the disk can be accessed.
981020 W The managed disk error count warning threshold has
been met.
981022 I Managed disk offline imminent, offline prevention
started
981025 I Drive firmware download started
981026 I Drive FPGA download started
Chapter 9. Event reporting 117
|||
|

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
BrandIBM
ModelStorwize V7000
CategoryStorage
LanguageEnglish

Related product manuals