Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
074001 W Unable to determine the vital product data (VPD) for an
FRU. This is probably because a new FRU has been
installed and the software does not recognize that FRU.
The cluster (system) continues to operate; however, you
must upgrade the software to fix this warning.
2040
074002 E The node warm started after a software error. 2030
076001 E The internal disk for a node has failed. 1030
076002 E The hard disk is full and cannot capture any more
output.
2030
076401 E One of the two power supply units in the node has
failed.
1096
076402 E One of the two power supply units in the node cannot
be detected.
1096
076403 E One of the two power supply units in the node is
without power.
1097
076502 E Degraded PCIe lanes on a high-speed SAS adapter. 1121
076503 E A PCI bus error occurred on a high-speed SAS adapter. 1121
076504 E A high-speed SAS adapter requires a PCI bus reset. 1122
076505 E Vital product data (VPD) is corrupt on high-speed SAS
adapter.
1121
076511 E A high-speed SAS controller is missing. 1032
076512 E Degraded PCIe lanes on a high-speed SAS adapter. 1032
076513 E A PCI bus error occurred on a high-speed SAS adapter. 1032
076514 E A high-speed SAS adapter requires a PCI bus reset. 1034
079500 W The limit on the number of cluster (system) secure shell
(SSH) sessions has been reached.
2500
079501 I Unable to access the Network Time Protocol (NTP)
network time server.
2700
081002 E An Ethernet port failure has occurred. 1401
082001 E A server error has occurred. 2100
084000 W An array MDisk has deconfigured members and has lost
redundancy.
1689
084100 W An array MDisk is corrupt because of lost metadata. 1240
084200 W An array MDisk has taken a spare member that is not an
exact match to the array goals.
1692
084201 W An array has members that are located in a different I/O
group.
1688
084300 W An array MDisk is no longer protected by an appropriate
number of suitable spares.
1690
084500 W An array MDisk is offline. The metadata for the inflight
writes is on a missing node.
1243
084600 W An array MDisk is offline. Metadata on the missing node
contains needed state information.
1243
Chapter 9. Event reporting 129

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
BrandIBM
ModelStorwize V7000
CategoryStorage
LanguageEnglish

Related product manuals