The recommended actions for these alerts guide you in correcting the situation.
Bad blocks are cleared by deallocating the volume disk extent by deleting the
volume or by issuing write I/O to the block. It is good practice to correct bad
blocks as soon as they are detected. This action prevents the bad block from being
propagated when the volume is replicated or migrated. It is possible, however, for
the bad block to be on part of the volume that is not used by the application. For
example, it can be in part of a database that has not been initialized. These bad
blocks are corrected when the application writes data to these areas. Before the
correction happens, the bad block records continue to use up the available bad
block space.