EasyManuals Logo

IBM TS4300 3555 User Manual

IBM TS4300 3555
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
Table 36. Warning events (continued)
Event Code Message Text and Description Details and Solution
4093 Couldn’t obtain an IP address from DHCP
server.
Check the network conguration settings and
check if the DHCP server is reachable.
Use the network conguration menu or
unplug the network cable and plug it in after a
few seconds to trigger an automatic
reconguration of the network interface.
4095 Library test failed. Not enough valid
cartridges available for testing.
Load the cartridges into the library.
4098 System time synchronization with SNTP
failed.
Check for valid SNTP server address in Time
conguration. If correct, ensure that the server
is reachable from your network and not
blocked by a rewall.
4099 An unexpected reset of accessor was
detected.
Ensure that the spooling cable is fully seated in
the base module and connected correctly to
the accessor assembly. If the error recurs,
replace the accessor assembly.
4113 Move from drive failed. Check for labels or cartridge misalignments
that prevents the cartridge from coming out of
the slot or drive.
4117 Drive disabled because no power supply
available.
Remove all affected drives, insert, and power
up at least one power supply to the failing
module. Wait 10 seconds and put the drives
back into the module.
4119 Drive disabled because internal IP address
unknown.
Remove affected drive, wait 10 seconds, and
put it back into the module.
Restart Library stack.
4120 No empty drive available for system test. Make sure that at least one empty drive and
one compatible cartridge are available.
4121 No compatible media available for system
test.
Make sure that at least one empty drive and
one compatible cartridge are in the drive.
4122 No cartridge available for slot to slot
exerciser test.
Make sure that at least one cartridge and one
empty slot are in the library.
4123 No empty slot available for slot to slot
exerciser test.
Make sure that at least one cartridge and one
empty slot are in the library.
4124 Drive or media statistics couldn’t be
retrieved when the tape was unloaded.
Check for more warning tickets. Replace media
if media-related tape alert flags reported.
4126 Cartridge was found in inaccessible slot of
lowermost unit.
Bottom slots from the lowermost unit are
inaccessible to the accessor. Place the
cartridge in an upper slot.
4127 Drive was restarted because of canister
reset.
Verify that the drive is installed properly in its
slot and thumb screws are tightened. If the
error persists, replace the drive.
100 IBM TS4300 Tape Library Machine Type 3555: User's Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS4300 3555 and is the answer not in the manual?

IBM TS4300 3555 Specifications

General IconGeneral
Maximum Number of Drives2
EncryptionYes
Product TypeTape Library
Power SupplyRedundant power supplies
Drive TypeLTO-6
Max Capacity (LTO-6)192 TB (compressed)
WeightApproximately 85 lbs
Operating Temperature10°C to 35°C
InterfaceFibre Channel, SAS
Host InterfaceFibre Channel, SAS

Related product manuals