104
CONTROL COMMAND
1
2
3
4
5
6
7
8
9
10
11
12
13
15
16
17
19
20
21
14
18
14
#MD 3UBCMD Data $ESCRIPTION
1A 05 0030 00 Send/read BW Popup (PBT) setting OFF
01 Send/read BW Popup (PBT) setting ON
0031 00 Send/read BW Popup (FIL) setting OFF
01 Send/read BW Popup (FIL) setting ON
0032 00 Send/read SSB/CW Synchronous Tuning
function OFF
01 Send/read SSB/CW Synchronous Tuning
function ON
0033 00 Send/read LSB selection for CW normal
side
01 Send/read USB selection for CW normal
side
0034 00 Send/read KEYER-Root selection for
keyer 1st menu
01 Send/read KEYER-SEND selection for
keyer 1st menu
0035 00 Send/read external keypad OFF
01 Send/read KEYER SEND selection for the
external keypad
0036 00 Send/read USB audio squelch OFF
(OPEN)
01 Send/read USB audio squelch ON
0037 0000 to
0255
Send/read USB modulation level
TO
0038 00 Send/read MIC selection for the modula-
tion input during DATA mode OFF
01 Send/read ACC selection for the modula-
tion input during DATA mode OFF
02 Send/read MIC+ACC selection for the
modulation input during DATA mode OFF
03 Send/read USB selection for the modula-
tion input during DATA mode OFF
0039 00 Send/read MIC selection for the modula-
tion input during DATA mode operation
01 Send/read ACC selection for the modula-
tion input during DATA mode operation
02 Send/read MIC+ACC selection for the
modulation input during DATA mode op-
eration
03 Send/read USB selection for the modula-
tion input during DATA mode operation
0040 00 Send/read CI-V transceive OFF
01 Send/read CI-V transceive ON
0041 00 Send/read CI-V selection for “USB” (COM
port) function
01 Send/read RTTY selection for “USB”
(COM port) function
0042 00 Send/read 300 bps selection for RTTY De-
code Baud rate
01 Send/read 1200 bps selection for RTTY
Decode Baud rate
02 Send/read 4800 bps selection for RTTY
Decode Baud rate
03 Send/read 9600 bps selection for RTTY
Decode Baud rate
04 Send/read 19200 bps selection for RTTY
Decode Baud rate
0043 00 Send/read Calibration marker OFF
01 Send/read Calibration marker ON
0044 0000 to
0255
Send/read reference frequency
TO
0045 see p. 107 Send/read SSB RX HPF/LPF setting
0046 00 to 10 Send/read SSB RX Tone (Bass) level
(00=–5 to 10=+5)
0047 00 to 10 Send/read SSB RX Tone (Treble) level
(00=–5 to 10=+5)
#MD 3UBCMD Data $ESCRIPTION
1A 05 0048 00 to 10 Send/read SSB TX Tone (Bass) level
(00=–5 to 10=+5)
0049 00 to 10 Send/read SSB TX Tone (Treble) level
(00=–5 to 10=+5)
0050 see p. 107 Send/read SSB TX bandwidth for WIDE
0051 see p. 107 Send/read SSB TX bandwidth for MID
0052 see p. 107 Send/read SSB TX bandwidth for NAR-
ROW
0053 see p. 107 Send/read AM RX HPF/LPF setting
0054 00 to 10 Send/read AM RX tone (Bass) level
(00=–5 to 10=+5)
0055 00 to 10 Send/read AM RX Tone (Treble) level
(00=–5 to 10=+5)
0056 00 to 10 Send/read AM TX tone (Bass) level
(00=–5 to 10=+5)
0057 00 to 10 Send/read AM TX Tone (Treble) level
(00=–5 to 10=+5)
0058 see p. 107 Send/read FM RX HPF/LPF setting
0059 00 to 10 Send/read FM RX tone (Bass) level
(00=–5 to 10=+5)
0060 00 to 10 Send/read FM RX Tone (Treble) level
(00=–5 to 10=+5)
0061 00 to 10 Send/read FM TX tone (Bass) level
(00=–5 to 10=+5)
0062 00 to 10 Send/read FM TX Tone (Treble) level
(00=–5 to 10=+5)
0063 see p. 107 Send/read CW RX HPF/LPF setting
0064 see p. 107 Send/read RTTY RX HPF/LPF setting
0065 00 Send/read Normal selection for contest
number style
01 Send/read “190 ANO” selection for con-
test number style
02 Send/read “190 ANT” selection for con-
test number style
03 Send/read “90 NO” selection for contest
number style
04 Send/read “90 NT” selection for contest
number style
0066 01 Send/read M1 selection for count up trig-
ger channel
02 Send/read M2 selection for count up trig-
ger channel
03 Send/read M3 selection for count up trig-
ger channel
04 Send/read M4 selection for count up trig-
ger channel
0067 0001 to
9999
Send/read present number
(0001=1 to 9999=9999)
0068 0000 to
0255
Send/read CW sidetone gain
TO
0069 00 Send/read CW sidetone gain limit OFF
01 Send/read CW sidetone gain limit ON
0070 01 to 60 Send/read CW keyer repeat time
(01=1 sec. to 60=60 sec.)
0071 00 Send/read Normal selection for message
display
01 Send/read Message selection for message
display
0072 28 to 45 Send/read CW keyer dot/dash ratio
(28=1:1:2.8 to 45=1:1:4.5)
0073 00 Send/read 2 msec. selection for Rise time
01 Send/read 4 msec. selection for Rise time
02 Send/read 6 msec. selection for Rise time
03 Send/read 8 msec. selection for Rise time