107
CONTROL COMMAND
14
s-EMORYKEYERCONTENTS
Command : 1A 02
X
q: Channel data
w–&1: Text data
XXX
……
XX
01:M1
02:M2
03:M3
04:M4
s#HARACTERSCODE
#HARACTER !3#))CODE $ESCRIPTION
0–9 30–39 Number
A–Z 41–5A Alphabetical characters
a–z 61–7A Alphabetical characters
space 20 Word space
/ 2F Symbol
? 3F Symbol
, 2C Symbol
. 2E Symbol
@ 40 Symbol
^5E
e.g., to send BT, enter ^BT
1
2A Inserts contest number (can be
used for 1 channel only)
s#7MESSAGECONTENTS
Command : 17 Up to 30 characters
While transmitting in the CW mode, or if the Break-in
function is ON, the transceiver transmits CW code
when the PC sends Command 17.
To send CW messages, the following character codes
are used.
s#HARACTERSCODE
#HARACTER !3#))CODE $ESCRIPTION
0–9 30–39 Number
A–Z 41–5A Alphabetical characters
a–z 61–7A Alphabetical characters
space 20 Word space
/ 2F Symbol
? 3F Symbol
. 2E Symbol
– 2D Symbol
, 2C Symbol
: 3A Symbol
’ 27 Symbol
( 28 Symbol
) 29 Symbol
= 3D Symbol
+ 2B Symbol
” 22 Symbol
@ 40 Symbol
sh&&vSTOPSSENDING#7MESSAGES
sh>vISUSEDTOTRANSMITASTRINGOFCHARACTERSWITH
no inter-character space.
s3PLITOFFSETFREQUENCYSETTING
Command : 1A 05 0012, 0013
1 kHz digit: 0–9
100 Hz digit: 0 (fixed)
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0 (fixed)
1 MHz digit: 0–9
Direction:
00: + direction
01: – direction
q
0XXXXXX
we
0
r
s33"TRANSMISSIONBANDWIDTHSETTING
Command : 1A 05 0050, 0051, 0052
XX
Lower edge
Higher edge
Lower edge
0: 100Hz
1: 200Hz
2: 300Hz
3: 500Hz
Higher edge
0: 2500Hz
1: 2700Hz
2: 2800Hz
3: 2900Hz
s28(0&AND,0&SETTINGSINEACH
OPERATINGMODE
Command : 1A 05 0045, 0053, 0058, 0063, 0064
XXXX
LPF (upper side)
HPF (lower side)
HPF
0: through
1 to 20: 100 to 2000 Hz
LPF
5 to 24: 500 to 2400 Hz
25: through
Set the LPF value larger than HPF one.
D Data content description (continued)