SET MODE
Connectors
»
SET > Connectors
MIC Jack 8V Output
Selects whether or not to output 8 V from the [MIC]
jack.
•
• ON: Output 8 V from the [MIC] jack.
REF OUT (Default: Auto (CX-10G:ON))
Sets the timing of the reference frequency signal
• Auto (CX-10G:ON): Automatically outputs the
reference signal only when the
optional CX-10G is connected.
• ON: Outputs the reference signal
anytime.
Network
»
SET > Network
DHCP (Valid after Restart) (Default: ON)
•
• ON: Uses the DHCP function. If a DHCP server is
in your network environment, the IP address
is automatically obtained.
IP Address (Valid after Restart)
(Default: 192.168.0.10)
Sets the static IP address.
L You cannot set the same address as “Default Gateway.”
Subnet Mask (Valid after Restart)
(Default: 255.255.255.0(24 bit))
Sets the subnet mask to connect to your PC or Local
Area Network (LAN), through your Router.
Default Gateway (Valid after Restart)
(Default: . . . .)
Sets the Default Gateway of the IC-905.
When you remotely control the IC-905 or use the
Internal Gateway function, a Default Gateway setting
is required.
Primary DNS Server (Valid after Restart)
(Default: . . . .)
Sets the Primary DNS Server address.
2nd DNS Server (Valid after Restart)
(Default: . . . .)
If there are two DNS server addresses, sets the
secondary DNS server address.
Network Name
If you are operating the IC-905 using the optional
RS-BA1 or transferring a picture to the IC-905 using
the optional ST-4001W, enter a network name of up to
15 characters.
»
SET > Network > Remote Settings
Network Control (Valid after Restart)
Selects whether or not to remotely control the IC-905.
•
• ON: Enables remote control of the IC-905.