58
12
CONNECTION AND INSTALLATION
2001 NEW 2001 NEW
D Fuse replacement
q Unscrew 4 cap-bolts from the top case.
Use 6 mm (
1
4) allen wrench.
w Open the transceivers main unit, then disconnect
1 at and 2 coaxial cables as shown below.
e Unscrew 32 screws from the shield covers, then
open the covers.
r Replace the circuitry fuse as shown in the diagram
below.
Use the supplied FGB 5 A fuse.
t Attach the shield covers, at cable, coaxial cables
and top case to their original position.
Fuse in DC-DC converter unit
Fuse in
PA unit
Flat cable
Coaxial cables
Fuse replacement
The transceiver has 2 fuses to protect internal circuitry.
If the transceiver stops functioning, check the fuses
below.
DC-DC converter unit ……………………… FGB 5 A
PA unit ……………………………………… FGB 5 A
CAUTION: DISCONNECT the DC power cable from
the transceiver when changing a fuse.