Page #198 background image
8: J1939 C
OMMUNICATION
8-30 FC6A S
ERIES
M
ICRO
S
MART
A
LL
-
IN
-O
NE
T
YPE
C
OMMUNICATION
M
ANUAL
FC9Y-B1730
(9) Import PGNs button
Imports PGNs saved as a CSV file.
Select the group where the PGNs will be imported in the group list. PGNs that are already registered to the selected group are
all deleted before the import is executed.
Click this button to display the Open dialog box.
Select the CSV file where the PGNs are saved and click Open to import the PGNs in that file to the PGN list for the group
selected in the group list.
(10) Export PGNs button
Exports the PGNs registered to the group selected in the group list as a CSV file.
Click this button to display the Save As dialog box.
Select the location to save the file, enter a file name, and then click Save to save the PGNs registered to the group as a CSV
file.
(11) PGN list
Displays the PGNs registered to the group selected in the group list.
(12) Select button
Closes PGN Manager and sets CAN ID in the calling message parameter to the PGN selected in the PGN list.
(13) Close button
Closes PGN Manager.
No.: Displays the control number for the registered PGN (1 to 65,535).
PGN: Displays the PGN.
Name: Displays the PGN name.