IDS 816 700-283-02I Issued September 2009
Sub-location 13 Auto Arm Delay
This location selects the delay period for the keypad buzzer warning, which is initiated before the panel
auto arms. At the completion of the Auto Arm Delay, the panel will arm. A valid user code entered during
the delay period will cancel the auto arming.
0 3 seconds 8 (Default) 2 minutes
1 10 seconds 9 3 minutes
2 15 seconds 10 4 minutes
3 20 seconds 11 5 minutes
4 25 seconds 12 10 minutes
5 30 seconds 13 15 minutes
6 45 seconds 14 18 minutes
7 1 minute 15 21 minutes
Sub-location 14 Reserved
Partition Reporting Codes (for 4 x 2 & Domestic)
For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting code,
a double zero (00) must be entered into the corresponding location. Note that if one of the above-
mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not be
reported. The exception to this rule is when using domestic reporting where only the first digit is used.
Sub-location 16 Duress Reporting Code
This code is reported when a duress code is entered.
Sub-location 17 Keypad Panic Reporting Code
This code is reported when the [P] key on a keypad is held down for one second.
Keypad Fire Reporting Code
This code is reported when the [F] key on the keypad is held down for one second.
Sub-location 19 Keypad Medical Reporting Code
This code is reported when the [M] key on the keypad is held down for one second.
Sub-location 20 Keypad Lockout Reporting Code
This code is reported when a keypad lockout condition occurs.
Sub-locations 21 – 44 Partition Programmable Outputs
See “System Programmable Outputs” (Section 9, page 30) for details on programming the
programmable outputs. The table below summarises the partition specific events that can be assigned to
the outputs.