- Dry and refi t the connector.
- Dry and refi t the connector.
- If it is not ok, change the wiring.
- Replace the main board.
Check that moisture has not made a
short circuit on connector J3.
Check that the connector on the
motor is not wet.
Check continuity and state of the
wiring.
Motor functions when
it should not or motor
does not get activated
at all.
FAULT 01 - MOTOR FAULT
STATE
INTERVENTION TO BE PERFORMED
CORRECTIVE ACTIONS
- Refi t the motor connection.
- Change the wiring.
- If not ok, change the motor.
- If there is not voltage, replace the main board.
Check motor connections, J3 on PCB.
Check continuity and state of the
wiring (J3).
Check protector of the motor.
Check that there is voltage (220V)
on the pins 1 and 2 and 3 on the
connector J3.
This fault appears after 32 minutes.
FAULT 02 – MOTOR NOT WIRED
STATE
INTERVENTION TO BE PERFORMED
CORRECTIVE ACTIONS
No motor action; drum
not turning
ARISTON
INDESIT
ARISTON
INDESIT