EasyManuals Logo

Industrial Data Systems IDS 430 User Manual

Default Icon
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
IDS 430/433 Users Manual Version 1.0
- 22 -
# 4 Axle Weigh – Short Scale
Automatically weigh multiple axles (or containers), print each axle weight, and
print axle (or containers) total.
Installation
Connect the Red light / Green light relays.
Green light = TTL out 1 TB4 Pin 1
Red light = TTL out 2 TB4 Pin 2
Ground = GND TB4 - Pin 4
+ 5 volts DC +5v TB3 - Pin 1
Setup Parameters
Configure the following parameters:
Parameter 43 Trip level weight. Determines when an axle is on the scale.
Parameter 74, 1 Red light turn delay timer. This provides a delay time before
the Red light output is turned on.
Parameter 74, 2 Green light turn delay timer. The amount of delay time
before the Green light is turned on.
Parameter 74, 3 Finish timer. Amount of time to wait before automatically
activating the finish print function.
Operators Functions
The unit is capable of operating unattended, with no operator intervention. The
indicator determines when an axle is on the scale by the increase (or decrease)
of weight on the scale.
A finish timer (parameter 74-3) determines when to complete a weigh cycle (print
total and wait for empty scale).
Press the F1 key to manually finish a weigh cycle before finish timer has timed
out.
Press the F2 key to abort the weigh cycle.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Industrial Data Systems IDS 430 and is the answer not in the manual?

Industrial Data Systems IDS 430 Specifications

General IconGeneral
BrandIndustrial Data Systems
ModelIDS 430
CategoryMeasuring Instruments
LanguageEnglish