EasyManuals Logo

Industrial Data Systems IDS 430 User Manual

Default Icon
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
IDS 430/433 Users Manual Version 1.0
- 26 -
# 7 Peak Hold Function
The peak hold register maintains the peak weight detected by the weight
indicator.
Enable Peak Hold
Access configuration parameter 75. Enter a 1 to enable peak hold, enter a 0 to
disable peak hold.
Clear Peak Hold Register
Press the CLEAR key to reset the peak hold register to 0.
Use the Scale Basic built in function Clear Peak [143] to reset the peak hold
register.
Display Peak Weight
Use the GROSS/NET key to scroll thru the display options as follows:
Initial mode: Display gross weight. Gross LED on.
First GROSS/NET press: Display net weight. Net LED on.
Next GROSS/NET press: Display gross peak weight. Gross LED flashing.
Next GROSS/NET press: Display net peak weight. Net LED flashing.
Next GROSS/NET press: Display gross weight. Gross LED on.
Etc.
Print Peak Weight
Use function 65 (Configure Print Formats) to format the print output using page 1:
Print Item 19: Print Gross Peak weight on page 1.
Print Item 20: Print Net Peak weight on page 1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Industrial Data Systems IDS 430 and is the answer not in the manual?

Industrial Data Systems IDS 430 Specifications

General IconGeneral
BrandIndustrial Data Systems
ModelIDS 430
CategoryMeasuring Instruments
LanguageEnglish