# 7 Peak Hold Function
The peak hold register maintains the peak weight detected by the weight
indicator.
Enable Peak Hold
Access configuration parameter 75. Enter a 1 to enable peak hold, enter a 0 to
disable peak hold.
Clear Peak Hold Register
Press the CLEAR key to reset the peak hold register to 0.
Use the Scale Basic built in function Clear Peak [143] to reset the peak hold
register.
Display Peak Weight
Use the GROSS/NET key to scroll thru the display options as follows:
Initial mode: Display gross weight. Gross LED on.
First GROSS/NET press: Display net weight. Net LED on.
Next GROSS/NET press: Display gross peak weight. Gross LED flashing.
Next GROSS/NET press: Display net peak weight. Net LED flashing.
Next GROSS/NET press: Display gross weight. Gross LED on.
Etc.
Print Peak Weight
Use function 65 (Configure Print Formats) to format the print output using page 1:
Print Item 19: Print Gross Peak weight on page 1.
Print Item 20: Print Net Peak weight on page 1.