— 64 —
No
Function
Command
RW
Min
Max
Default
Step
Parameter
115
Projector High Power
Hours
LTO
R
0
9999
Displays the numbers of
hours that the projector
has run in High Power
(Normal) mode over its
life (including all lamps).
116V
Projector Info menu
PRI
W
1
1
Display Projector Info
menu
117
Projector Low Power
Hours
LTE
R
0
9999
Displays the numbers of
hours that the projector
has run in Low Power
(Eco) mode over its life
(including all lamps).
118V
Projector Model
MDL
R
string
119V
Projector Resolution
NRS
R
string
1080p
121V
Projector Total Hours
LMT
R
0
9999
1
123V
Lamp Hour Reset
LRT
RW
n/a
1
n/a
1
Reset Lamp Hour
(OSD:Status)
126V
Search Screen
DSU
RW
0
4
0
1
0:Black
1:Red
2:Green
3:Blue
4:White
130V
Sharpness
SHP
RW
0
31
14
1
155V
System State
SYS
R
0
18
0
1
0:Standby
2:Start Up
12:Cooling
18:Error
158V
Tint
TNT
RW
0
100
50
1
160V
Tracking
MTS
RW
-5
5
0
1
RGB source only
-5~5
162V
Vert. Keystone
DKV
RW
-40
40
0
1
164V
Vert. Position
VPS
RW
-5
5
0
1
RGB source only
(VPS?) to get range
(VPS+)
(VPS-)
167V
Volume
VOL
RW
0
10
5
1
0~10

Table of Contents