X1 Service Guide 66
LED repeats 3 flash sequence
The lamp was operating but shut down. Fans are
running. The status LED flashes a repeated
red three-flash sequence.
Open the lamp door and
check the lamp calble
connector to make sure
it's fully seated.
Solve the
problem?
No
Replace the ballast/
power supply ECA.
(page 6)
If the projector fails to start properly, you
may see the status LED flash a repeated
single-flash sequence indicating that the
lamp won't strike. Go to page xxx to solve
failure to strike problems.
Replace the lamp.
(page 42)
Solve the
problem?
No
Yes
Run the projector long
enough to ensure that the
problem is solved.
Yes
Repeat the diagnostic
process to ensure that
the problem is solved.
(page 62)