9.2.1 USING INOLOADER SOFTWARE
To update the firmware with the InoLoader software it is necessary a USB-C cable, and a computer to run the
software.
Connect the USB-C cable to the laptop and the MD800 and follow the below procedure:
Start the InoLoader software and select the USB interface
as the communication port.
Set the Station number:
Rectifier = 16
Axis 1 = 1
Axis 2 = 2
….
Axis 8 = 8
Upper option module = 14
Lower option module = 15
Select the firmware file and click on the download button
to download it to the device.