19
INOVANCE TECHNOLOGY EUROPE GmbH
MD800 EtherCAT Starting Guide_EN_v1.1_20211109.docx
6.3.4 RELATED PARAMETERS
The following table shows the rectifier parameters related to the SI-ECAT board.
Communication
protocol selection
1:CANopen
2:CANlink
3:Optional
communications
card
Set to 1, for CANopen communication.
Set to 2, for CANlink communication.
Set to 3, which is the communication
card mode. (SI-ECAT mode)
Missing station
start function
It can also be operated when the
mapping relationship is configured
without this station
Row.
Displays the station number assigned to
the slave by the master during EtherCAT
communication.
Assigns a station number to the slave
during EtherCAT communication in case
of a master unable to assign the slave
station number automatically.
FD‑71 = 0: The master assigns the
station number automatically.
FD‑71 ≠ 0: Use the set station number,
with the one assigned by the master
deactivated.
Number of SYNC
interrupts
allowed by
EtherCAT
Defines the maximum number of master
signal loss events allowed by the slave.
EtherCAT port 0/1
Data forwarding
error
EtherCAT
processing unit
And PDI error
If data exchange error occurs between
ESC and internal MCU, keep the setpoint
to 0. If the counting value increases,
the internal anti-interference
performance of the board is abnormal.
If data link loss is detected by the ESC
port, the counting value of the
corresponding link loss counter
increases.
Such scenario may be caused by poor
contact or damaged cables.
0~1 0 Used to check for setting failure
(loss of synchronization) Testing
mechanism