7. Description of Parameters MD500 User Manual
- 106 -
7 Description of Parameters
6WDUW6WRS&RPPDQG6RXUFH
The MD500 AC drive has the following three control methods to start and to stop the MD500 AC drive.
ƕ Operating panel keys
ƕ Terminal control
ƕ Communication control
You can select the proper control mode in function parameter F0-02.
Function Code Parameter Name Setting Range Default
F0-02 Command source selection 0: Operation panel control (LED off)
1: Terminal control (LED on)
&RPPXQLFDWLRQFRQWURO/('ÁDVKLQJ
0
ƕ ) 2SHUDWLRQSDQHOFRQWURO7KH/2&$/5(027LQGLFDWRULVRII
The run commands are given by pressing keys
RUN
and
STOP
RES
on the operation panel.
–
Press
RUN
to start the AC Drive.
–
Press
STOP
RES
to stop the AC Drive.
For details of the operation panel, refer to chapter 4.
ƕ ) 7HUPLQDOFRQWURO7KH/2&$/5(027LQGLFDWRULVRQ
The terminal control mode applies to installations where the Start and Stop signals come from:
–
A DIP switch or electromagnetic button, or
–
A dry contact signal source
Commands are given by using multi-functional input terminals with functions such as FWD, REV, JOGF and JOGR.
For details on the terminal control, see section 7.1.1 Terminal Control.
ƕ ) &RPPXQLFDWLRQFRQWURO7KH/2&$/5(027LQGLFDWRULVÁDVKLQJ
7KHPRVWFRPPRQFRQÀJXUDWLRQIRUWKH0'XVHVDKRVWFRPSXWHUWRFRQWUROWKH$&GULYHWKURXJKDFRPPXQLFDWLRQOLQN
such as Modbus, PROFIBUS-DP, CANlink, or CANopen.
For details on the communication control, see section 7.1.2 Communication Control.