MD500 User Manual 6. Parameter Table
- 85 -
6.2 Standard Parameters
Parameter No. Parameter Name Setting Range Default Property
Group F0: Standard Parameters
F0-00 *3W\SHGLVSOD\ 1 and 2 Model
dependent
ƕ
F0-01 Motor 1 control mode 0 to 2 0 *
F0-02 Command source selection 0 to 2 0
ƿ
F0-03 Main frequency reference
setting channel selection
WR 0
ƾ
F0-04 Auxiliary frequency reference
setting channel selection
WR 0
ƾ
F0-05 Base value of range of auxiliary
frequency reference for Main
and auxiliary superposition
0, 1 0
ƿ
F0-06 Range of auxiliary frequency Y for
Main and auxiliary superposition
0% to 150% 100%
ƿ
F0-07 Frequency source
superposition selection
00 to 34 00
ƿ
F0-08 Preset frequency 0.00 to max. frequency (F0-10) 50.00 Hz
ƿ
) Rotation direction 0 and 1 0
ƿ
F0-10 Max. frequency 50.00 to 500.00 Hz 50.00 Hz
ƾ
F0-11 Source of frequency upper limit 0 to 5 0
ƾ
F0-12 Frequency upper limit Frequency lower limit (F0-14) to
maximum frequency (F0-10)
50.00 Hz
ƿ
F0-13 Frequency upper limit offset 0.00 Hz to max. frequency (F0-10) 0.00 Hz
ƿ
F0-14 Frequency lower limit 0.00 Hz to frequency upper limit (F0-12) 0.00 Hz
ƿ
F0-15 Carrier frequency 0.5 to 16.0 kHz Model
dependent
ƿ
F0-16 &DUULHUIUHTXHQF\DGMXVWHG
with temperature
0, 1 1
ƿ
F0-17 Acceleration time 1 VWRV)
VWRV)
VWRV)
Model
dependent
ƿ
F0-18 Deceleration time 1 VWRV)
VWRV)
VWRV)
Model
dependent
ƿ
) $FFHOHUDWLRQ'HFHOHUDWLRQ
time unit
0: 1s
1: 0.1s
2: 0.01s
1
ƾ
F0-21 Frequency offset of Auxiliary
frequency setting channel for
Main and auxiliary superposition
0.00 Hz to max. frequency (F0-10) 0.00 Hz
ƿ
efesotomasyon.com