MD500 User Manual 7. Description of Parameters
7.8.4 Motor 2 Parameters
The MD500 supports driving two motors at different time. For the two motors, you can:
ƕ Set motor nameplate parameters respectively
ƕ Perform motor auto-tuning respectively
ƕ 6HOHFW9)FRQWURORUYHFWRUFRQWUROUHVSHFWLYHO\
ƕ Set encoder-related parameters respectively
ƕ 6HWSDUDPHWHUVUHODWHGWR9)FRQWURORUYHFWRUFRQWUROLQGHSHQGHQWO\
0RWRUSDUDPHWHUVDUHGHÀQHGWKHVDPHDVPRWRUSDUDPHWHUV)RUGHWDLOVVHHWKHGHVFULSWLRQVRIJURXSV)DQG)
You can select the desired motor parameter group in F0-24 or via a DI terminal
1. Select the desired motor parameter group in F0-24.
Function Code Parameter Name Setting Range Default
F0-24 Motor parameter group selection 0: Motor parameter group 1
1: Motor parameter group 2
0
2. Select the desired motor parameter group via a DI terminal.
6HWDQ\RI)WR)IRUWKHIXQFWLRQ0RWRUVHOHFWLRQ,IWKH',LVRIIWKHPRWRUSDUDPHWHUJURXSLVVHOHFWHG,IWKH',LV
on, the motor parameter group 2 is selected.
Function Code Parameter Name Setting Description
$Q\RI)WR) DIx function selection 41 Motor selection
Note
ƕ ,IDQ\RI)WR)LVVHWIRUWKHIXQFWLRQ´0RWRUVHOHFWLRQµWKH',WHUPLQDORYHUULGHV),IQRQHRI
)WR)LVVHWIRUWKHIXQFWLRQ´0RWRUVHOHFWLRQµWKHPRWRUVHOHFWLRQLVGHWHUPLQHGE\)
ƕ Switchover of the two groups of motor parameters is prohibited during
the drive running. Otherwise, the drive reports Err41.
Function Code Parameter Name Setting Range Default
A2-00 Motor type selection 0 to 1 0
A2-01 Rated motor power 0.1 to 1000.0 Model
dependent
A2-02 Rated motor voltage 1 to 2000 Model
dependent
A2-03 Rated motor current WR$&GULYHSRZHUN:
0.1 to 6553.5 (AC drive power > 55 kW)
Model
dependent
A2-04 Rated motor frequency 0.01 to max. frequency Model
dependent
A2-05 Rated motor speed 1 to 65535 Model
dependent
A2-06 Stator resistance WR$&GULYHSRZHUN:
0.0001 to 6.5535 (AC drive power > 55 kW)
Auto-tuning
parameter
A2-07 Rotor resistance WR$&GULYHSRZHUN:
0.0001 to 6.5535 (AC drive power > 55 kW)
Auto-tuning
parameter
A2-08 Leakage inductive reactance WR$&GULYHSRZHUN:
0.001 to 65.535 (AC drive power > 55 kW)
Auto-tuning
parameter
$ Mutual inductive reactance WR$&GULYHSRZHUN:
0.01 to 655.35 (AC drive power > 55 kW)
Auto-tuning
parameter