7. Description of Parameters MD500 User Manual
- 216 -
2XWSXW2YHUFXUUHQW3URWHFWLRQ
This is to provide the overcurrent protection for the AC drive.
If the drive's output current is equal to or smaller than the value set in F8-36 and the duration exceeds the value set in F8-37, the
digital output terminal set for function 36 becomes on.
)LJXUH2XWSXWFXUUHQWOLPLW
Time
Time
F8-36
ON
F8-37
Output current
Output overcurrent
detection signal
Function Code Parameter Name Setting Range Default
F8-36
Output overcurrent threshold 0.0% (no detection)
0.1% to 300.0% (rated motor current)
200.0%
F8-37 Output overcurrent detection delay 0.00s to 600.00s 0.00s
7.11.10 Any Current Detection
The MD500 provides two groups of current detection level and width.
,IWKHGULYHVRXWSXWFXUUHQWUHDFKHVWKHZLGWKWKHGLJLWDORXWSXWWHUPLQDOVVHWIRUIXQFWLRQVDQGEHFRPHRQ
Figure 7-70 Any current detection
OFF
OFF
OFF
ON ON ON
Output current
Current detection level
Current detection signal
Current detection width
Current detection width
DO or relay
Function Code Parameter Name Setting Range Default
F8-38
Detection level of current 1 0.0% to 300.0% (rated motor current)
100.0%
)
Detection width of current 1 0.0% to 300.0% (rated motor current)
0.0%
F8-40
Detection level of current 2 0.0% to 300.0% (rated motor current)
100.0%
F8-41
Detection width of current 2 0.0% to 300.0% (rated motor current)
0.0%