MD500 User Manual 5. Quick Setup
- 75 -
CONTINUE Para. Parameter name Default Commissioning
If any digital input is used
Set DI function
F4-00 DI1 function selection 1
F4-01 0: No function
1: Forward RUN (FWD)
2: Reverse RUN (REV)
3: Three-wire control
4: Forward JOG (FJOG)
5: Reverse JOG (RJOG)
6: Terminal UP
7: Terminal DOWN
8: Coast to stop
)DXOWUHVHW5(6(7
10: RUN pause
11: External fault normally open (NO) input
12: Multi-reference terminal 1
13: Multi-reference terminal 2
14: Multi-reference terminal 3
15: Multi-reference terminal 4
7HUPLQDOIRUDFFHOHUDWLRQGHFHOHUDWLRQWLPHVHOHFWLRQ
7HUPLQDOIRUDFFHOHUDWLRQGHFHOHUDWLRQWLPHVHOHFWLRQ
18: Frequency source switchover
83DQG'2:1VHWWLQJFOHDUWHUPLQDONH\SDG
20: Command source switchover terminal 1
$FFHOHUDWLRQ'HFHOHUDWLRQSURKLELWHG
22: PID pause
23: PLC status reset
24: Swing pause
25: Counter input
26: Counter reset
27: Length count input
28: Length reset
7RUTXHFRQWUROSURKLELWHG
30: Pulse input (enabled only for DI5)
31: Reserved
,PPHGLDWH'&LQMHFWLRQEUDNLQJ
CONTINUE Para. Parameter name Default Commission