Product Information
‑14‑
Item Unit Specifications
Input Rated input current (heavy
load)
A 12 22 41
Rated input current (light
load)
A 16 33 44
Power capacity (heavy
load)
kVA 10 18.3 34.1
Power capacity (light load) kVA 13.3 27.4 36.6
Mains type ‑ TN, TT, IT
Rated voltage & Rated
frequency
‑ Three phase 380 VAC to 480 VAC, 50/60 Hz
Voltage range ‑ ‑15% to +10%; actual allowed range: 323 VAC to 528 VAC
Frequency range ‑ ±5%; actual allowed range: 47 Hz to 63 Hz
Output Output voltage V 510 VDC to 720 VDC
Rated output current
(heavy load)
A 12.2 22.4 41.8
Rated output current (light
load)
A 16 33 44.6
Efficiency (heavy load) ‑ 99.2% 99.2% 99.3%
Efficiency (light load) ‑ 99.2% 99.1% 99.3%
Overload capability ‑ Heavy load: 60s for 150% with the rated current; Light load: 60s
for 110% with the rated current
Thermal
design
Thermal design power
(heavy load)
W 42 75 131
Thermal design power
(light load)
W 58 120 157
Air flow CFM 16 30 30
Cooling mode ‑ Forced air cooling
Overvoltage category ‑ OVC III
Pollution degree ‑ PD2
IP rating ‑ IP40 (excluding terminals and fans)
Noise dB(A) 33 60 60
Table 1–4 Electrical parameters of the single‑axis drive unit (three‑phase 380–480 V)
Item Unit Specifications
Model: MD800‑1‑4T_ _ (S) ‑ 1R8 3R4 4R8 5R5 9R5 13 17
Power (heavy load) kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Power (light load) kW 0.75 1.5 2.2 3.7 5.5 7.5 11
Size ‑ S1
Weight (gross/net) kg 1.1/0.9 1.1/
0.9
1.1/
0.9
1.1/
0.9
1.1/
0.9
1.1/
0.9
1.1/
0.9