Item Unit Specifications
Input Rated input current (heavy
load)
A 2.3 4.2 6 6.9 11.8 16.2 21.2
Rated input current (light
load)
A 2.6 5.7 6.7 11.2 16.1 21.1 26
Input voltage 510 VDC to 720 VDC
Applicable
motor
Heavy load kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Light load 0.75 1.5 2.2 3.7 5.5 7.5 11
Heavy load HP 0.5 1 2 3 5 7.5 10
Light load 1 2 3 5 7.5 10 15
Output Output voltage V 0 to AC input voltage
Output frequency Hz 0 to 590
Rated output current (heavy
load)
A 1.8 3.4 4.8 5.5 9.5 13 17
Rated output current (light
load)
A 2.1 4.6 5.4 9 13 17 21
Efficiency (heavy load) 96.2% 97.0% 98.0% 98.4% 98.6% 98.7% 98.7%
Efficiency (light load) 97.7% 98.0% 98.4% 98.4% 98.6% 98.6% 98.5%
Carrier frequency kHz V/f: 0.8 kHz to 15 kHz (6 kHz by default)
SVC: 2 kHz to 7 kHz (6 kHz by default)
Overload capability Heavy load: 60s for 150% with the rated current
Light load: 60s for 110% with the rated current
Thermal
design
Thermal design power
(heavy load)
W 22 32 42 47 70 98 122
Thermal design power (light
load)
W 24 41 47 80 99 136 197
Air flow CFM 0 4 4 4 9.5 10 13
Cooling mode Natural air
cooling
Forced air cooling
Overvoltage category OVC III
Pollution degree PD2
IP rating IP40 (excluding terminals and fans)
Noise dB(A) 0 33 33 33 47 51 59
Table 1–5 Electrical parameters of the dual‑axis drive unit (three‑phase 380–480 V)
Item Unit Specifications
Model: MD800‑2‑4T_ _ (S) 1R8 3R4 4R8 5R5 9R5
Power (heavy load) kW 0.4 0.75 1.5 2.2 3.7
Power (light load) kW 0.75 1.5 2.2 3.7 5.5
Size S1
Weight (gross/net) kg 1.3/1.1 1.3/1.1 1.3/1.1 1.3/1.1 1.3/1.1