EasyManua.ls Logo

Inovance MD800 Series - 2.3.2 Cables; 2.3.3 Accessory Kit

Inovance MD800 Series
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Information
16
Item Unit Specifications
Input Rated input current (heavy
load)
A 4.5 8.5 12 13.7 23.7
Rated input current (light
load)
A 5.3 11.5 13.5 22.4 29.8
Input voltage 510 VDC to 720 VDC
Motor Heavy load kW 0.4 0.75 1.5 2.2 3.7
Light load 0.75 1.5 2.2 3.7 5.5
Heavy load HP 0.5 1 2 3 5
Light load 1 2 3 5 7.5
Output Output voltage V 0 to AC input voltage
Output frequency Hz 0 to 590
Rated output current
(heavy load)
A 1.8 3.4 4.8 5.5 9.5
Rated output current (light
load)
A 2.1 4.6 5.4 9 12
Efficiency (heavy load) 96.1% 97.0% 97.9% 98.4% 98.6%
Efficiency (light load) 97.7% 98.0% 98.4% 98.4% 98.6%
Carrier frequency kHz V/f: 0.8 kHz to 15 kHz (6 kHz by default)
SVC: 2 kHz to 7 kHz (6 kHz by default)
Overload capability Heavy load: 60s for 150% with the rated current
Light load: 60s for 110% with the rated current
Thermal
design
Thermal design power
(heavy load)
W 45 64 85 98 141
Thermal design power
(light load)
W 49 82 95 163 198
Air flow CFM 4 4 6 9.5 13
Cooling mode Forced air cooling
Overvoltage category OVC III
Pollution degree PD2
IP rating IP40 (excluding terminals and fans)
Noise dB(A) 33 33 44 47 59
Single-phase 200–240 V
Table 1–6 Electrical parameters of the power supply unit (single‑phase 200–240 V)
Item Unit Specifications
Model: MD800‑0‑2S_ _ (B) 24 40
Power (heavy load) kW 2.2 3.7
Power (light load) kW 3 4.4
Size S2
Weight (gross/net) kg 1.7/1.5 1.9/1.7