Product Information
‑17‑
Item Unit Specifications
Input Rated input current (heavy
load)
A 24 40
Rated input current (light
load)
A 27 44
Power capacity (heavy
load)
kVA 5.8 9.6
Power capacity (light load) kVA 6.5 10.6
Mains type ‑ TN, TT, IT
Rated voltage & Rated
frequency
‑ Single‑phase 200 VAC to 240 VAC, 50/60 Hz
Voltage range ‑ ‑15% to +10%; actual allowed range: 170 VAC to 264 VAC
Frequency range ‑ ±5%; actual allowed range: 47 Hz to 63 Hz
Output Output voltage V 270 VDC to 360 VDC
Rated output current
(heavy load)
A 13.5 22.6
Rated output current (light
load)
A 15.1 24.8
Efficiency (heavy load) ‑ 98.1% 98.1%
Efficiency (light load) ‑ 98.7% 98.1%
Overload capability ‑ Heavy load: 60s for 150% with the rated current
Light load: 60s for 110% with the rated current
Thermal
design
Thermal design power
(heavy load)
W 59 94
Thermal design power
(light load)
W 65 110
Air flow CFM 25 30
Cooling mode ‑ Air cooling
Overvoltage category ‑ OVC III
Pollution degree ‑ PD2
IP rating ‑ IP40 (excluding terminals and fans)
Noise dB(A) 53 60
Table 1–7 Electrical parameters of the single‑axis drive unit (single‑phase 200–240 V)
Item Unit Specifications
Model: MD800‑1‑2T_ _ (S) ‑ 1R7 3 5 8 11
Power (heavy load) kW 0.2 0.4 0.75 1.5 2.2
Power (light load) kW 0.4 0.75 1.5 2.2 3.7
Size ‑ S1
Weight (gross/net) kg 1.1/0.9 1.1/0.9 1.1/0.9 1.1/0.9 1.1/0.9