EasyManua.ls Logo

Inovance NICE900 Series - Page 47

Inovance NICE900 Series
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Function Code Table
- 46 -
Function
Code
Parameter Name Setting Range Default
Min.
Unit
Property
F4-01
Door close startup
acceleration time
0.1–999.9s 1.0s 0.1s
F4-02
Low speed running time for
door close startup in speed
control
0.1–999.9s 1.0s 0.1s
F4-03 Door close normal speed 0.00 Hz to F1-04 12.00 Hz
0.01
Hz
F4-04 Door close acceleration time 0.1–999.9s 2.0s 0.1s
F4-05 Door close ending low speed 0.00 Hz to F4-03 2.00 Hz
0.01
Hz
F4-06 Door close deceleration time 0.1–999.9s 1.5s 0.1s
F4-07 Door close limit low speed 0.00 Hz to F4-03 1.00 Hz
0.01
Hz
F4-08
Low speed running time at
door close limit
0–9999 ms 300 ms 1 ms
F4-09 Door vane retraction speed 0.00 to F4-03 2.00 Hz
0.01
Hz
F4-10
Door vane retraction running
time
0–9999 ms 500 ms 1 ms
F4-11
Torque switchover threshold
at door close limit
0.0%–150.0% 50.0% 0.1%
F4-12
Door close limit holding
torque
0.0%–150.0% 30.0% 0.1%
F4-13 Door close hindered torque 0.0%–150.0% 100.0% 0.1
F4-14
Working mode upon door
close hindered
0: Reserved
1: Output door close
hindered signal
2: Immediate stop
3: Door re-open
1 1
F4-15
Door close hindered judging
time
0–9999 ms 500 ms 1 ms
F4-16
Door close normal speed at
re emergency
5.00 to F1-04 10.00 Hz
0.01
Hz
F4-17
Normal speed at door close
hindered
F4-18 to F1-04 12.00 Hz
0.01
Hz
F4-18
Low speed at door close
hindered
0.00 Hz to F1-04 2.00 Hz
0.01
Hz
F4-19 Normal speed torque 0.00%–150.0% 100.0% 0.1%
F4-20 Low speed torque 0.00%–150.0% 100.0% 0.1%
Group F5: Door Open/Close Auxiliary Parameters
F5-00
Abnormality deceleration
time
0.1–5.0s 0.3s 0.1

Table of Contents

Related product manuals