Chapter 5 Function Code Table
- 47 -
Function
Code
Parameter Name Setting Range Default
Min.
Unit
Property
F5-01 Door open time limit 0–999.9s 30.0s 1s
☆
F5-02 Door close time limit 0–999.9s 0s 1s
☆
F5-03 Low speed running time limit 0–999.9s 0s 1s
☆
F5-04
Delay of external door open
command
0–999.9s 60.0s 1s
☆
F5-05
Delay of external door close
command
0–999.9s 60.0s 1s
☆
F5-06 Door open curve 0, 1 1 1
★
F5-07
Start segment time of door
open acceleration S curve
10.0%–50.0% (acceleration/
deceleration time, start
segment + rising segment ≤
90%)
20.0% 0.1%
★
F5-08
Rising segment time of door
open acceleration S curve
10.0%–80.0% (acceleration/
deceleration time, start
segment + rising segment ≤
90%)
60.0% 0.1%
★
F5-09
Start segment time of door
open deceleration S curve
10.0%–50.0% (acceleration/
deceleration time, start
segment + falling segment ≤
90%)
20.0% 0.1%
★
F5-10
Falling segment time of door
open deceleration S curve
10.0%–80.0% (acceleration/
deceleration time, start
segment + falling segment ≤
90%)
60.0% 0.1%
★
F5-11
Start segment time of door
close acceleration S curve
0, 1 1 1
★
F5-12
Rising segment time of door
close acceleration S curve
10.0%–50.0% (acceleration/
deceleration time, start
segment + rising segment ≤
90%)
20.0% 0.1%
★
F5-13
Start segment time of door
close deceleration S curve
10.0%–80.0% (acceleration/
deceleration time, start
segment + rising segment ≤
90%)
60.0% 0.1%
★
F5-14
Falling segment time of door
close deceleration S curve
10.0%–50.0% (acceleration/
deceleration time, start
segment + falling segment ≤
90%)
20.0% 0.1%
★
F5-15
Start segment time of door
open acceleration S curve
10.0%–80.0% (acceleration/
deceleration time, start
segment + falling segment ≤
90%)
60.0% 0.1%
★
F5-16 Speed deviation threshold 0%–80% 50% 0%
☆
F5-17
Time for determining speed
deviation too large
0–5000 ms 400 ms 1 ms
☆