Chapter 5 Function Code Table
- 48 -
Function
Code
Parameter Name Setting Range Default
Min.
Unit
Property
F5-18
Door close steady speed
delay
0–9999 ms 200 ms 1 ms
★
F5-19 Fault braking current 0.1%–150.0% 100% 0.1%
★
Group F6: Distance Control Parameters
F6-00
Door width auto-tuning
function
0: Disabled
1: Enabled
0 1
★
F6-01 Door width auto-tuning speed 0 to F0-04 3.00 Hz
0.01
Hz
☆
F6-02 Low bits of door width pulse 0–9999 0 1
★
F6-03 High bits of door width pulse 0–9999 0 1
★
F6-04
Low speed running distance
of door open startup in
distance control
0.0%–30.0% 10.0% 0.1%
☆
F6-05
Door open slow-down point
in distance control
60.0%–90.0% 70.0% 0.1%
☆
F6-06
Door open limit point in
distance control
80.0%–99.0% 96.0% 0.1%
☆
F6-07
Low speed running distance
of door close startup in
distance control
0.0%–30.0% 10.0% 0.1%
☆
F6-08
Door close slow-down point
in distance control
60.0%–90.0% 70.0% 0.1%
☆
F6-09
Door close limit point in
distance control
80.0%–99.0% 96.0% 0.1%
☆
F6-10 Output torque display 0.0-1–80.0% 0.0% 0.1%
☆
F6-11
Low bits of the door open
limit switch position
0–9999 0 1
★
F6-12
High bits of the door open
limit switch position
0–9999 0 1
★
F6-13
Position of the door close
limit switch
0–9999 0 1
★
F6-14
Torque setting for door width
auto-tuning or initial running
0.0%–150.0% 80.0% 0.1%
★
F6-15
Low bits of the pulse of door
open slow-down point
0–9999 0 1
★
F6-16
High bits of the pulse of door
open slow-down point
0–9999 0 1
★
F6-17
Low bits of the pulse of door
close slow-down point
0–9999 0 1
★
F6-18
High bits of the pulse of door
close slow-down point
0–9999 0 1
★