Chapter 5 Function Code Table
- 49 -
Function
Code
Parameter Name Setting Range Default
Min.
Unit
Property
F6-19
Pulse at door open limit
output
0.0%–99.9% 0.0% 0.1%
☆
F6-20
Pulse at door close limit
output
0.0%–99.9% 0.0% 0.1%
☆
F6-21 Door position feedback pulse 0.0%–99.9% 33.0% 0.1%
☆
Group F7: Distance Control Parameters
F7-00
Door open limit holding time
in demonstration mode
1.0–999.9s 0.1s 2.0s
★
F7-01
Door close limit holding time
in demonstration mode
1.0–999.9s 0.1s 2.0s
★
F7-02
Actual door open and close
times in demonstration mode
0–9999 0 1
☆
F7-03
Limit of door open and close
times in demonstration mode
0–9999 0 1
☆
Group F8: Auxiliary Parameters
F8-00 Software version 0.00–99.99 1.00 0.01
●
F8-01 Module temperature 0–100°C 0°C 1°C
●
F8-02 Fault auto reset times 0–100 0 1
★
F8-03 Brake use ratio 0–100% 100% 1%
☆
F8-04 Accumulative power-on time 0–9999 h 0 1
★
F8-05
Reserved (working time:
minutes)
0 0 1
★
F8-06 Accumulative running time 0–9999 h 0 1
★
F8-07
Reserved (working time:
minutes)
0 0 1
★
F8-08
Accumulative working time
setting
0–9999 h 0 1
★
F8-09
Accumulative operation time
setting
0–9999 h 0 1
★
F8-10 Auxiliary function selection 0–9999 12 1
★
F8-12 Drive function selection 0–9999 0 1
★
F8-14 Overload coefcient 0–10.00 2.00 0.01
☆
Group F9: Auxiliary Parameters
F9-00 Terminal lter time 0–100 ms 20 ms 1 ms
☆