Electromagnetic Compatibility
Design Guide 41
7.4 Magnetic Leakage Field - Required
A PFC choke magnetic leakage field must not cause any interference with a high-
resolution computer monitor placed next to or on top of the end-use chassis.
7.5 Voltage Fluctuations and Flicker – Required
The power supply shall meet the specified limits of EN61000-3-3 (IEC 61000-3-3) and
amendment A1 to EN 61000-3-3 (IEC 61000-3-3/A1) for voltage fluctuations and
flicker for equipment drawing not more than 16VAC, connected to low voltage
distribution systems.
§ §