EasyManuals Logo

Intel ATX12VO User Manual

Intel ATX12VO
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
Environmental
72 613768
7 Environmental
The following subsections define environmental specifications and test parameters,
based on the typical conditions to which a power supply may be subjected during
operation or shipment.
7.1 Temperature (Recommended)
Operating ambient +10 °C to +50 °C (At full load, with a maximum temperature
rate of change of 5 °C/10 minutes, but no more than 10 °C/hr)
Non-operating ambient -40 °C to +70 °C (Maximum temperature rate of change of
20 °C/hr)
7.2 Thermal Shock (Shipping)
Non-operating -40 °C to +70 °C
15 °C/min ≤ dT/dt ≤ 30 °C/min
Tested for 50 cycles; Duration of exposure to temperature extremes for each half
cycle shall be 30 minutes.
7.3 Humidity (Recommended)
Operating to 85% relative humidity (non-condensing)
Non-operating to 95% relative humidity (non-condensing)
Note: 95% relative humidity is achieved with a dry bulb temperature of 55 °C and a
wet bulb temperature of 54 °C.
7.4 Altitude (Recommended)
Operating to 10,000 ft.
Non-operating to 50,000 ft.
7.5 Mechanical Shock (Recommended)
Non-operating 50 g, trapezoidal input; velocity change ≥ 170 in/s
Three drops on each of six faces are applied to each sample.