Intel® Server Board S1200SP Family Technical Product Specification
119
Full Sensor Name
(Sensor name in
SDR)
Contrib.
To System
Status
07 - Rebuild/Remap in
progress
Note:
1. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply).
Note that power supply redundancy may be lost even when both supplies are operational if the system is loaded beyond the capacity of a
single power supply.
2. This is only applicable when the system doesn't support redundant fans. When fan redundancy is supported, then the contribution to system
state is driven by the fan redundancy sensor, not individual sensors. On a system with fan redundancy, the individual sensor severities will
read the same as the fan redundancy sensor’s severity.
3. This is only applicable when the system doesn't support redundant power supplies. When redundancy is supported, then the contribution to
system state is driven by the power unit redundancy sensor. On a system with power supply redundancy, the individual sensor severities will
read the same as the power unit redundancy sensor’s severity.