Intel
®
True Scale Fabric Switches 12000 Series
July 2015 User Guide
Doc. Number: G91930 Revision: 005US 49
This trap indicates that a module was removed from the chassis.
icsChassisTrapModuleFailed
This trap indicates that a module has failed and is not operational.
icsChassisTrapModuleSelfTestFailure
This trap indicates that the module failed one or more of its self tests.
icsChassisTrapModuleEEPROMReadFailure
This trap indicates that an error condition was encountered when reading the
EEPROM of the module.
icsChassisTrapModuleFPGAReadFailure
This trap indicates that an error condition was encountered when reading the Field-
Programmable Gate Array (FPGA) of the module.
icsChassisTrapModuleBulkPowerFailure
This trap indicates that the bulk power used by a module has failed within the
chassis.
icsChassisTrapModuleReboot
This trap indicates that the module is in the process of rebooting.
Power Group
icsChassisTrapPowerSupplyNotResponding
This trap indicates that a power supply is not responding to HEARTBEAT poll
requests that are issued by the internal chassis management service.
icsChassisTrapPowerSupplyInserted
This trap indicates that a power supply was inserted into the chassis.
icsChassisTrapPowerSupplyRemoved
This trap indicates that a power supply was removed from the chassis.
icsChassisTrapPowerSupplyFailed
This trap indicates that a power supply has failed and is not operational.
icsChassisTrapPowerSupplyEEPROMReadFailure
This trap indicates that an error condition was encountered when reading the
EEPROM of the power supply.
icsChassisTrapPowerSupplyFanFailed
This trap indicates that a power supply fan has failed and is not operational.
Fan Group
icsChassisTrapFanNotResponding
This trap indicates that a fan is not responding to HEARTBEAT poll requests that are
issued by the internal chassis management service.
icsChassisTrapFanTrayInserted
This trap indicates that a fan was inserted into the chassis.
icsChassisTrapFanTrayRemoved
This trap indicates that a fan was removed from the chassis.
icsChassisTrapFanFailed
This trap indicates that a fan has failed and is not operational.
icsChassisTrapFanTrayEEPROMReadFailure
This trap indicates that an error condition was encountered when reading the
EEPROM of the fan tray.