Intel
®
True Scale Fabric Switches 12000 Series
User Guide July 2015
48 Doc. Number: G91930 Revision: 005US
3. Select or deselect the desired trap(s).
Note: To generate an immediate trap, click the applicable Gen Trap button.
4. To save settings, click on Apply.
The following are definitions for each chassis trap:
Chassis Group
icsChassisTrapSystemSelfTestFailure
This trap indicates that the chassis failed one or more of its self-test(s).
icsChassisTrapSystemReboot
This trap indicates that the chassis is in the process of rebooting.
icsChassisTrapSystemMgmtSrvcStarted
This trap indicates that the internal service used to support the management of the
chassis is operational.
icsChassisTrapSystemMgmtSrvcAborted
This trap indicates that the internal service used to support the management of the
chassis has terminated abnormally.
icsChassisTrapSystemSwitchFailover
This trap indicates that there was a fail over from one switch in the chassis to the
other.
Slot Group
icsChassisTrapModuleNotResponding
This trap indicates that a module is not responding to HEARTBEAT poll requests,
that are issued by the internal chassis management service.
icsChassisTrapModuleInserted
This trap indicates that a module was inserted into the chassis.
IcsChassisTrapModuleRemoved
Figure 3-40. Chassis Trap Control Window