EasyManua.ls Logo

Intergraph TDZ 2000 GL2 - System Power Management

Intergraph TDZ 2000 GL2
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
Specifications
The following specifications apply to the TDZ 2000 GL2 and ExtremeZ GL2.
Item
Specifications
Dimensions
25.8 x 7.9 x 20.2 inches (65.4 x 20.0 x 50.8 cm)
Maintenance
clearance
36 inches (91.4 cm) front and back
AC line voltage (US) 90 - 132 VAC, 47 - 63 Hz, 1 phase, 15A/125 V receptacle
AC line voltage
(International)
180 - 264 VAC, 47 - 63 Hz, 1 phase, 15A/250 V receptacle
Recommended room
temperature
50
°
to 80
°
F (10
°
to 26
°
C)
Recommended room
humidity
20% to 80% (non-condensing)
Heat dissipation 2,662.14 BTU/hr
Hardware Monitoring
TDZ 2000 GL2/ExtremeZ GL2 systems feature advanced hardware monitoring.
The InterSite Hardware Monitor software reports the following key voltages and system
states:
u
All major voltages, including processor bus voltage; +5 V; +3.3 V; +12 V; -12 V; -5 V
u
Processor voltage ID
u
Temperature at two locations (near primary processor and near expansion slots)
u
Fan speed
u
Low battery voltage alert
u
SMART Drive system compliance

Table of Contents

Other manuals for Intergraph TDZ 2000 GL2