EasyManuals Logo

Interlogix NS3552-8P-2S-V2 User Manual

Interlogix NS3552-8P-2S-V2
511 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #290 background imageLoading...
Page #290 background image
Chapter 4: Web configuration
288 NS3552-8P-2S-V2 User Manual
The page includes the following fields:
Object Description
ID Indicates the index of alarm control entry.
Interval Indicates the interval in seconds for sampling and comparing the rising and
falling threshold.
Variable Indicates the particular variable to be sampled
Sample Type The method of sampling the selected variable and calculating the value to be
compared against the thresholds.
Value The value of the statistic during the last sampling period.
Startup Alarm The alarm that may be sent when this entry is first set to valid.
Rising Threshold Rising threshold value.
Rising Index Rising event index.
Falling Threshold Falling threshold value.
Falling Index Falling event index.
Buttons
• Click Refresh to refresh the page immediately.
• Click the Auto-refresh check box to refresh the page automatically. Automatic
refresh occurs every three seconds.
• Click I<< to update the table starting from the first entry in the alarm table (i.e., the
entry with the lowest ID).
• Click >> to update the table starting with the entry after the last entry currently
displayed.
RMON event configuration
Configure the RMON Event table on the RMON Event Configuration page. The entry
index key is ID.

Table of Contents

Other manuals for Interlogix NS3552-8P-2S-V2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix NS3552-8P-2S-V2 and is the answer not in the manual?

Interlogix NS3552-8P-2S-V2 Specifications

General IconGeneral
BrandInterlogix
ModelNS3552-8P-2S-V2
CategorySwitch
LanguageEnglish

Related product manuals