EasyManua.ls Logo

International Electronics prox.pad plus - B Quick Program Feature; C Programming Code ONLY Use; D Programming Code and Card Use

International Electronics prox.pad plus
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2.2.B Quick Program Feature
A “quick program” feature has been implemented for
user data, however. You only need to enter the user’s
location and the keypad PIN (or present card), in the
format noted below. Employing the quick feature auto-
matically selects a “Normal” user access type.
loc#PIN*PIN*
OR
loc # ** <present card>
4.2.2.C Programming Code ONLY Use
You can program a user Code ONLY use with com-
mand 50. The program sequence is as follows:
50 # user-type # user location # keypad
PIN * keypad PIN *
4.2.2.D Programming Code AND Card Use
The format for programming a user for both Code
AND Card use is as follows:
50 # user-type # user location # keypad
PIN * keypad PIN * <present c ard>
When a combination code/card user employs the
prox.pad plus unit, that user can present the proximity
cardfirstattheproximityreader,orenterthecode
first at the prox.pad plus keypad as desired.
After the code/card user either presents the card at the
reader or enters the code on the keypad, the red and
green LEDs alternate. This indicates that the unit is
awaiting the second part of the transaction before
granting access. After the second part of the transaction
is completed successfully, the bi-color LED turns solid
green and the door opens.
Chapter 4: Programming 4.2 P rogramming Users
4-10 prox.pad plus Install/Program. Manual, PPP, D2

Table of Contents